OWL, INC. WTO-S15 CALIBRATION and OWL, INC. WTO-S15 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the OWL, INC. WTO-S15 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another OTDR? Shop for Comparable Products on our   new OTDR page

 
   OWL, INC. WTO-S15   Description / Specification:    
OWL, INC. WTO-S15 OWLTrek OTDR

The Optical Wavelength Laboratories WTO-S15 OWLTrek OTDR is pocket-sized, but the large 2.8" high-resolution color LCD display can show even the longest traces with ease. And, for greater viewing flexibility and trace detail, OWL has implemented state-of-the-art MEMS technology which "flips" the high-resolution color LCD display between portrait and landscape mode automatically. In landscape mode, a wider viewing area means greater viewing detail. Automatic event location is an advanced feature normally found only in expensive, high-end OTDRs. The OWLTrek OTDR now brings this feature to the entry-level OTDR market. While in event location mode, the OWLTrek OTDR marks events on the trace, has an event table showing the location, type, reflectance level, and loss of each event, and auto-zooms to the selected event. Specifications. Output Wavelength: 1550 nm. Fiber Type: Singlemode. Dynamic Range (SNR=1)( Using maximum pulse width): 23 dB. Distance Range: 80 miles (128 kilometers). Event Dead Zone: 2 meters (typical). Attenuation Dead Zone: 7 meters (typical). Maximum Data Points: 64000. Data Point Spacing: Up to 64km: 1 meter // Over 64km: 2 meters. Pulse Width: 1, 2, 5, 10, 20, 50, 100, 200, 500, 1000 meters. Index of Refraction: 1.4000 to 1.6000. Distance Accuracy: Up to 64km: 1 + (distance in meters/10000) // Over 64km: 2 + (distance in meters/10000). Number of Stored Traces: Maximum trace distance: up to 200 // Minimum trace distance: 3000+.



 

Standard Calibration $350.00 *
*This is a Web introductory price for one calibration of the OWL, INC. WTO-S15. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Amplified Spontaneous Emission Source (ASE)
ASE, a process where spontaneously emitted radiation (luminescence) is amplified. In lasers and particularly in high-gain erbium-doped amplifiers, amplified spontaneous emission is usually an unwanted effect. It tends to limit the gain achievable in a single stage of a fiber optic amplifier to the order of 40–50 dB.

Dynamic Range
In a transmission system, the ratio of the overload level to the noise level of the system, usually expressed in dB. Ratio of the highest to lowest detectable signal of a system, expressed in dB.

Optical Power
Optical Power is usually measured in "dBm", or decibels referenced to one miliwatt of power. while loss is a relative reading, optical power is an absolute measurement, referenced to standards. You measure absolute power to test transmitters or receivers and relative power to test loss.

Relative Wavelength Accuracy
When randomly changing the wavelength and measuring the differences between the actual and displayed wavelengths, the relative wavelength accuracy is ± half the span between the maximum and the minimum value of all differences.

Wavelength
Wavelength is a term for the color of light, usually expressed in nanometers (nm) or microns (m). In Fiber Optics the wavelenghts mostly used are in the infrared region where the light is invisible to the human eye.


Please contact us for your OWL, INC. WTO-S15 CALIBRATION and/or OWL, INC. WTO-S15 OWLTrek OTDR REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?